Home Locks GSM thermostat "GSM-Climate ZONT H1". Buy from an authorized dealer. Profitable price. Delivery across the Russian Federation! Intelligent thermostat Zont GSM-Climate H1 - indoor temperature monitoring, remote control of the heating boiler, failure notification

GSM thermostat "GSM-Climate ZONT H1". Buy from an authorized dealer. Profitable price. Delivery across the Russian Federation! Intelligent thermostat Zont GSM-Climate H1 - indoor temperature monitoring, remote control of the heating boiler, failure notification

Boiler remote control unit ZONT H-1 GSM-Climate

  • Supply voltage 10-14 V
  • Maximum current consumption 150 mA
  • Maximum current through relay contacts 1000 mA
  • GSM modem frequency bands 800, 900, 1800, 1900 MHz
  • Weight: 200 g

ZONT H-1 GSM-Climate is a modern device for controlling a heating boiler via the Internet and telephone.

It automatically controls the operation of the boiler, monitors its technical condition and signals in case of an accident or power failure.

Comfort temperature:

Using ZONT H-1 GSM-Climate, you can remotely change the parameters of the heating system and control the temperature in the room. At the same time, it is possible to switch to the “Economy” or “Comfort” fixed temperature mode, create a weekly “Schedule” for the operation of the heating boiler or turn it off remotely.
ZONT H-1 GSM-Climate independently monitors the readings of a digital air temperature sensor and corrects the operation of the boiler depending on the set parameters of the temperature regime in the room.

Remote control:

ZONT H-1 GSM-Climate is a compact device with its own SIM card connected to a heating boiler. Commands can be sent to it from any phone (satellite, mobile or fixed line), tablet or PC. Remote control requires a unique password to prevent unauthorized access.

Additional "Alarm input" provides connection of an unlimited number of detectors of the same type: motion or opening sensors, fire and smoke alarms, water or gas leakage sensors, and other similar equipment. Information is transmitted via mobile communication channels and the Internet. You simply specify the necessary phone numbers for notification in the system settings: yours or a security organization.

How does ZONT H-1 work in alarm mode?

Equipment is installed in the room, selected depending on the task being solved, for example, sensors that respond to movement. Such sensors detect the presence of strangers in the house and send a signal to the unit's GSM modem. An alarm notification is sent to the programmed telephone numbers in the form of a voice call or SMS message, and is also displayed in the personal account of the online service. Thus, you can quickly make a decision to protect your property: call the police or just call your neighbors.

Of course, the main function of ZONT H-1 is to control the operation of the heating boiler. But you must admit that home security is a very useful feature of this “smart” device. And we are talking not only about protection against the penetration of unauthorized persons, but also from other risks: fire, water and gas leaks.That is also a kind of insurance against domestic troubles.

Free WEB service:

  • Checking the health of an electric or gas boiler
  • Informing about an accident and power failure
  • Management of the boiler operating modes from the phone and via the Internet
  • Room temperature monitoring
  • Maintaining the temperature in the room according to an individual schedule
  • Notifications about the triggering of the alarm input sensors (GSM-signaling)
  • User-friendly interface and mobile applications for iOS and Android

Energy Saving:

If you are at home only on weekends or in the evening/night time, the ZONT H-1 GSM-Climate control unit will maintain the minimum temperature in the house in your absence, saving energy resources, and will create comfortable conditions in the house by the time you return.

Functionality:

Free WEB interface:

  • permanent connection with the server
  • recording and automatic transmission of accumulated information
  • boiler status display:
    • current mode of operation
    • room temperature
    • emergency mode indication
  • changing the boiler operating mode “in one click”
  • temperature monitoring for any period of time
  • weekly temperature schedule editor
  • notifications about triggering of additional sensors (Alarm input)

Boiler control:

  • SMS commands
  • dialing to the voice menu
  • through the Internet

Event Notification:

  • change in t below the set threshold
  • change in t above a set threshold
  • boiler failure
  • temperature sensor malfunction
  • loss and appearance of supply voltage
  • triggering of "Alarm input" sensors

Event memory:

  • room temperature at any given time
  • date and time of boiler failure
  • date and time of operation mode change
  • executed voice menu commands
  • sent SMS
  • date and time of software update (software)
  • date and time of power on/off

Specifications:

Supply voltage 10-14V
Maximum current consumption 150 mA
One analog input Yes
One dry contact output (make/break) Yes
Maximum current through relay contacts 1000 mA
Voice interface Yes
WEB interface Yes
1-wire interface Yes
Operating temperature range from -30 to +55 °С
GSM modem frequency bands 800, 900, 1800, 1900 MHz
GPRS data channel Yes
Backup battery BL-5C (optional) sold separately
Start-up time no more than 50 sec
dimensions 77 x 86 x 33 mm
Weight 200 gr
Housing material Plastic

Equipment:

  • Thermostat (Main unit of the system) - 1 pc.
  • Mounting base - 1 pc.
  • Digital temperature sensor - 1 pc.
  • Terminal block (2 pcs.) - 1 pc.
  • Network adapter 220/12 V - 1 pc.
  • GSM antenna - 1 pc.

Modern technologies have firmly entered the lives of many people and made it much more comfortable. Indeed, now we have access to many benefits of civilization, the existence of which was quite difficult to imagine a few years ago. One of the devices that allows you to create a new level of comfort is the system Zont H-1. This system helps to remotely control the temperature in the room, monitor the health of the heating boiler, and remotely control it!

Convenient control of the heating system

In the winter season, maintaining a comfortable climate in the house is usually provided by a whole group of heating devices, which are not always convenient to control manually. However, with the smart thermostat Zont H-1 you can easily customize your heating system to suit your needs. Thus, a comfortable temperature will be constantly maintained in the house.

Remote control

In addition, you have the opportunity to control the climate in the house at a distance! You can call or send the necessary command by SMS to enable any mode of operation, find out the balance SIM cards, the current state of the system, etc. This feature will be especially useful for users who may be away on business trips for a long time, leave the city, etc. You can remotely turn on the economical heating mode, and before returning home, create a comfortable heating temperature.

Creating a heating schedule

Zont H-1 allows you to configure the operation of the heating system in accordance with a specific schedule. For example, if you are at home only in the evening and on weekends, the system will maintain a minimum temperature in your absence and provide the necessary heating for your return. Thus, the system allows save energy and your funds.

How does the system work?

The thermostat can be controlled by voice menu, sending SMS-messages or via Internet service via PC or smartphone. To use the Internet service, you do not need to install special programs, any modern web browser(Opera, Chrome, IE 8 and above, Firefox). Access to the service is carried out through the user's personal page on the site zont-online.ru. You can also control the device using a special application for Android, which is available for download in Play market.

Through a personal account on the zont-online.ru service. the user needs to set comfortable temperature values, as well as threshold levels for generating alarms when the temperature deviates to a critical value.

Zont H-1 receives information about temperature changes using temperature sensor supplied with the system. Depending on the sensor readings, the thermostat turns off or turns on the output relay that controls the operation of the boiler. This principle of operation allows you to maintain the required temperature in the house.

In the event of a malfunction in the operation of the heating boiler, Zont H-1 will notify the owner, which will allow you to quickly respond to this event.

System functionality

    Room temperature alert:

    t˚above the set threshold

    t˚below the set threshold

    Notification when a malfunction occurs:

    in case of temperature sensor malfunction

    in case of boiler failure

    Event memory:

    temperature sensor readings

    SMS commands

    operating mode changes

  • power on/off

    software updates (software)

    Room temperature monitoring:

    update period - 1 minute

    Boiler operation mode control:

    SMS commands

    via internet service

    Internet access:

    permanent connection with the server

    viewing temperature graphs for any period of time

    display of the thermostat status (room temperature, current operating mode, emergency operation indication)

    transfer of accumulated data

    changing the thermostat operating mode “in one click”

    entering and editing settings

    weekly temperature schedule editor

    Remote software update:

    The current firmware version is updated from the user's personal account at his command.

    Supply voltage: 10-14V

    Maximum current consumption: 150mA

    One analog input

    One dry contact output (make/break)

    Maximum current through relay contacts: 1000 mA

    WEB interface

    1-wire interface

    Operating temperature range: from -30 to +55 °С

    GSM modem frequency bands: 800, 900, 1800, 1900 MHz

    GPRS data channel

    Built-in GSM antenna (can be optionally external)

    Internal non-volatile memory

    Backup battery: BL-5C 1000 mA*N (optional)

    Time to enter the operating mode: no more than 50 sec.

    Dimensions: 77 x 86 x 33 mm

    Weight: 0.200 kg.

    Plastic case

    Individual packing

    External GSM antenna

    Terminal block (2 pcs.)

    Mounting base

    Thermostat

    Digital temperature sensor

    Network adapter 220/12 V.

The thermostat is not supplied with a battery and a SIM card.


Total weight: 1.19 kg Sold: 29 Made in Russia

"ZONT H-1" - a module for remote monitoring and control of the heating boiler. Configuration and control are carried out via the GSM channel and via the Internet. In accordance with the set parameters, it automatically regulates the operation of the boiler in heating mode to maintain the desired temperature in the room. Also, the device can monitor the technical condition of the boiler and signal a malfunction in the event of an accident or a power outage.

Why buy "ZONT H-1"

  • Control from your phone, tablet or computer. Commands to the thermostat can be sent from any phone, tablet or PC. For the convenience of work, there are free applications for the phone and a personal account on the site. To protect against unauthorized access, the entrance to your personal account is protected by a password.
  • Individual setting of operating modes. It is possible to pre-set several home heating modes in order to select the desired mode at the moment with one movement.
  • 10 temperature sensors for any purpose. 10 temperature sensors (wired or radio sensors) can be connected to the thermostat at the same time. The readings of the main are used to control the operation of the boiler. An additional one is assigned to the reserve. In the event of a malfunction of the main thermostat, it automatically switches to work on the backup sensor and the boiler control does not stop. The readings of the remaining sensors are used for general monitoring of the heating system.
  • Alert system for all occasions. The thermostat controls the temperature in the house and on the street, the supply voltage, the technical condition of the boiler and much more. If the values ​​deviate from the preset values, it informs you about this by a call or SMS.
  • Easy installation that does not require special skills. Easily connects to an electric or gas boiler instead of a room thermostat. A SIM card of any operator providing stable reception is inserted into the device, and the supply voltage is applied. You need to send SMS to the SIM card number from the owner’s phone and “introduce” the devices.

Features of the GSM module "ZONT H1"

  • Through the free WEB-interface, the following possibilities are provided: real-time display of the current state of the boiler and the temperature in the room, control of the boiler operation mode, temperature monitoring (inside, outside the room, coolant) for any selected period of time, programming of the boiler operation according to a weekly schedule, display notifications about the operation of additionally installed sensors.
  • Remote control of the boiler operation can be carried out by SMS, dialing to the voice menu, via the Internet (WEB-interface and mobile application for Android and iOS devices).
  • Event notification: deviation of the measured temperature from the set threshold values, about a boiler failure (provided that the thermostat is connected to the emergency output of the boiler), a temperature sensor malfunction and the thermostat goes into emergency operation, power loss / restoration (mains) (only with a backup battery installed) .
  • Using the module for GSM security - monitoring the status of additional sensors (security or water leakage / gas leakage) connected to the "Alarm" input of the thermostat.
  • Event memory: a diary of measured temperatures for any period without a statute of limitations, date and time of detection of a boiler failure, date and time of changing the operating mode of the boiler and thermostat, a list of executed control commands through the voice menu, sent SMS, software updates, date and time of failure / restoration power supply (mains).
  • Remote software update without shutting down the module itself and dismantling it.

For which boilers is the GSM thermostat "ZONT H-1" suitable?

The ZONT H-1 module, in fact, is a simple room thermostat, but only made on a hardware platform using a GSM / GPRS modem and WEB technology. The principle of its operation and the method of connection to any gas or electric boiler is exactly the same as that of conventional thermostats. It is connected to the connector for the room regulator and controls the boiler, maintaining the set temperature according to the readings of its temperature sensor. To do this, the thermostat turns the boiler on or off by closing the contacts of its output relay.

Thus, if your boiler provides for the possibility of controlling commands from a room thermostat, then the ZONT H-1 thermostat can be used with it.

Specifications "ZONT H1"

Supply voltage 10-28V
Maximum current consumption 150 mA
Number of inputs 2
Dry contact output (make/break) 1
Type of connected wired temperature sensors DS 18S20
Type of connected radiothermal sensors ML-703
Total number of simultaneously connected temperature sensors 10
The maximum allowable length of the cable with temperature sensors 100 m
Maximum current through relay contacts 1000 mA
Maximum voltage of switched relay contacts ~120 V, =24 V
Voice interface There is
WEB interface There is
1-wire interface There is
Operating temperature range from -30 to +55 °С
GSM modem frequency bands 800, 900, 1800, 1900 MHz
Data link GPRS
GSM antenna external
Internal non-volatile memory There is
Start-up time no more than 50 seconds
Average service life 7 years
dimensions 77 x 86 x 33 mm
Weight no more than 200 g
Housing material ABC plastic

Delivery set "ZONT H-1"

  • Thermostat "GSM-Climate ZONT H-1".
  • Mounting base.
  • Power adapter 220 V.
  • GSM antenna.
  • Wired temperature sensor.
  • Screw terminals.
  • SIM card.
  • User guide.
  • Warranty card.
  • Corporate packaging.

GSM-Climate ZONT H-1 - remote control unit for heating boiler

  • Control of an electric or gas boiler from the phone and via the Internet;
  • Notification of the operation of security sensors (GSM-alarm);
  • Installation in a convenient place;
  • Controls the temperature in the house;
  • Saves resources for heating;
  • Maintains a comfortable temperature regime;
  • Warns of a boiler failure;
  • Informs about the penetration into the premises;
  • The maximum number of sensors - 5;
  • Recommended for self installation.

Among other things, Micro Line developed applications for Android and iOS, through which you can control the heating boiler from anywhere in the world.

An intelligent GSM thermostat will control your boiler so that it will heat your house only when it is really needed, maintaining a comfortable temperature in the house according to an individual schedule.

By entering the application, you can not only find out the temperature in the room, but also set the boiler to pre-set modes, turn it on to work on a schedule, or simply turn off the boiler.

Attention! For the correct operation of the GSM module in the territory of the Autonomous Republic of Crimea, a SIM card from the mobile operator "Volna mobile" is required.
Today Volna Mobile provides mobile data services in 2G, 3G, 4G standards throughout the Republic of Crimea and Sevastopol.

Control your comfort from your phone, tablet or computer

ZONT H-1 is a room thermostat with its own SIM card connected to a heating boiler. Commands can be sent to it from any phone, tablet or PC.

For the convenience of work, there are free applications for the phone and a personal account on the site. To protect against unauthorized access, the entrance to your personal account is password protected.

Individual setting of operating modes

Comfortable temperature for everyone is different. Some people like tropical heat, others think that 20-22 degrees is more than enough.

We have provided several home heating modes so that you can select the one you need at the moment with one movement.

In addition, you can easily create a weekly schedule for the operation of the heating boiler for the most optimal consumption of electricity or gas.

Safe operation of the boiler and comfortable temperature

The thermostat measures the temperature in the room and turns on or off the output relay, controlling the operation of the boiler in such a way that the temperature inside the room corresponds to the set value.

It monitors the technical condition of the boiler and signals in case of an accident or power failure.

Alert system for all occasions

The thermostat controls the temperature in the house and on the street, the supply voltage, the technical condition of the boiler and much more.

If the values ​​deviate from the set values, it informs you about this by a call or SMS.

10 temperature sensors for any purpose.

10 temperature sensors can be connected to the thermostat at the same time. It can be both wired and radio sensors.

The readings of the main are used to control the operation of the boiler. An additional one is assigned to the reserve. In the event of a malfunction of the main thermostat, it automatically switches to work on the backup sensor and the boiler control does not stop.

The readings of the remaining sensors are used for general monitoring of the heating system.

Easy installation that does not require special skills

ZONT H-1 is easily connected to an electric or gas boiler instead of a room thermostat. A SIM card of any operator that provides stable reception is inserted into it, and the supply voltage is applied. You need to send an SMS to the SIM card number from the owner’s phone and “introduce” the devices.

You do not have to pay to use the device

Pay only the actual costs of communication between you and the thermostat at the rates of the selected operator. And no subscription fee!

On which boilers can the ZONT thermostat be installed?

ZONT, ​​by its main purpose, is a simple room thermostat, but only made on a hardware platform using a GSM / GPRS modem and WEB technology.

The principle of its operation and the method of connection to any gas or electric boiler is exactly the same as that of conventional thermostats. It is connected to the connector for the room regulator and controls the boiler, maintaining the set temperature according to the readings of its temperature sensor. To do this, the thermostat turns the boiler on or off by closing the contacts of its output relay.

Thus, if your boiler provides for the possibility of controlling commands from a room thermostat, then the ZONT thermostat can be used with it.

Supply voltage 10-28V
Maximum current consumption 150 mA
Number of analog inputs 1
Dry contact output (make/break) 1
Type of connected wired temperature sensors DS 18S20
Type of connected radiothermal sensors ML-703
Total number of simultaneously connected temperature sensors 10
The maximum allowable length of the cable with temperature sensors 100 m
Maximum current through relay contacts 1000 mA
Maximum voltage of switched relay contacts ~ 120 V, = 24 V
Voice interface There is
WEB interface There is
1-wire interface There is
Operating temperature range from -30 to +55 °С
GSM modem frequency bands 800, 900, 1800, 1900 MHz
Data link GPRS
GSM antenna external
Internal non-volatile memory There is
Built-in backup battery Li-ion / 1000 mA*N (option)
Start-up time no more than 50 sec
Average service life 7 years
dimensions 77 x 86 x 33 mm
Weight, no more 0.200 kg
Housing material ABC plastic

Equipment data


  • Smart thermostat ZONT (ZONT models H-1, H-1V and H-2) is designed to meet the needs of holiday home users. The peculiarity of the situation is when there is no one in the house, but you need to be sure that the heating system is working. Moreover, the inertia of the heating system requires a change in the boiler mode long before the arrival of the owners. All this is solved with the help of our devices and Internet service. ZONT.

    Features and principle of operation

    Thermostat feature ZONT-H in that it is focused on the use of the Internet. Now the main trend in this area is the cloud service and the thermostat works exactly like that. Unlike most competitors, it lacks a home control panel. All monitoring and control operations are performed using either a personal computer or mobile devices - a smartphone or tablet. This significantly reduces the cost of equipment, while at the same time allows the user to control the situation, wherever he is.

    Thermostat ZONT-H works even when the connection is lost, executing a pre-set program, for example, a weekly schedule. Additionally, it is possible to use control commands in the form of SMS text and even using the voice menu.

    The user has the ability to use a highly functional and powerful graphical interface through a web browser or mobile application. Convenient and visual graphics, informational messages and settings are available. Data from the product is stored on the server and the user can view the entire history of events and parameters. The user interface has been carefully designed and highly acclaimed by numerous customers.

    To meet the needs of different user groups, various models are produced that differ in the type of communication - GSM or WiFi. Structurally, some models are made in a small-sized case of their own design, others - in a standard case on a DIN rail for installation in an electrical cabinet.

    The thermostat has 2 inputs for connecting various additional devices.
    On Input 1 can be connected: or ; or with signaled “Boiler failure”; or External room thermostat.

    On Input 2 can be connected: or Security sensors and detectors; or with signaled “Boiler failure”; or External room thermostat; or Interface opentherm And Radio module ML-489.

    - Security sensors and detectors , connected to one input must be of the same type according to the connection method. The number of sensors in the loop - ICD, MKD, etc. no more than 10 pieces; detectors of water leakage and gas leakage no more than 5 pcs. The maximum distance of the last in the loop is 100 m.

    - WITH signaled “Boiler failure”. To control the technical condition of the boiler and generate a notification about its emergency state, the thermostat can be connected to the emergency output of the boiler.

    - Room thermostat . When connecting an external room thermostat, it becomes possible to control the boiler both through ZONT-H 1 and through an external room thermostat, the choice of how the control is carried out is done remotely via the Internet service or SMS command "Manual mode".

    When operating from an external thermostat, remote monitoring of the room temperature and all notification modes (on an accident, power loss / restoration, alarm events, etc.) will be preserved.

    - Radio module ML-489. Thermostat interface module ZONT with radio devices It provides reception and relaying of information from radio devices to the ZONT server

    For boilers that have a computerized OpenTherm Interface there is an adapter that allows you to expand the functions of management and control, to ensure fuel economy due to advanced algorithms of the system.

    How to choose and operate thermostats ZONT?

    Models ZONT H-1 and ZONT H-1V have a GSM communication channel and are designed for very low Internet traffic. Therefore, the price of a subscription fee to a mobile operator is minimal

    The ZONT H-2 model has a WiFi communication channel and is used where a wireless local area network is already available.

    1. Internet traffic is about 60 MB per month*

    *indicated with rounding up to 100kb per hour

    It is important to take into account that the actual consumption of Internet traffic strongly depends on the nature of the use of the device and the quality of the connection. Accordingly, the worse the communication conditions, the more often the device reconnects to the server, and the more traffic is consumed.

    To make the monthly fee easily predictable, we recommend choosing tariffs with unlimited traffic.

    Many operators offer tariffs in which the Internet speed drops when a certain limit is reached. Such tariffs are also well suited, because ZONT devices do not have special requirements for connection speed.

    If you choose a tariff with a per-megabyte traffic payment, then pay attention to the amount of traffic rounding. With a large rounding value (for example, more than 100 KB), the operator can count many times more traffic than the device actually consumes. The smaller the rounding size, the better.

    2. Calls and SMS

    ZONT devices use voice calls and SMS messages only for alarm notification, therefore, choose a tariff based on the expected number of alerts.

    Attention! There are tariffs incompatible with work ZONTa

    • Since November 2015 on MTS Smart tariffsInternet work blocked in 3G modems . Along with modems, the operator also blocks our devices.
    • Option "Tablet XS" from MegaFondesigned only for tablets , and in ZONT devices either does not work at all, or leads to constant loss of communication.

    Important!

    Flashing is an extremely desirable step when you first turn it on. The fact is that in production the product receives the current firmware, and it is desirable for the user to have the latest one. So we advise you to reflash the thermostat before starting operation.

    Flashing should be carried out under the control of the user. Since the communication channel is usually unreliable, you need to make sure that the flashing procedure is successful and the product is back in touch.

    Video about ZONT H1V:

    youtube video

    How to set up a power outage alert

    Settings - thermostat setting - input No. 2 - "panic button"
    - - polarity of an emergency input - "short circuit on the earth"
    - - notifications - alarm events - "your phone" - "envelope"
    -save

    Instead of "input 2" you can also use "input 1". For ZONT-H1V, in principle, the same thing, just different contacts.

    The difference between ZONT H-1V and ZONT H-1 is as follows:

    • the relay in H-1V holds 220V. The relay in H-1 is rated for 120V;
    • ZONT H-1V has a 220V->5V adapter for converting a high-voltage boiler alarm signal (available in Vaillant) into a low-voltage one for the Zont input;
    • relays have the opposite logic - the information is outdated, it corresponds to products produced before xxx 2015 (see section "connection to the boiler"):
      • ZONT H-1 - the boiler heats up when the relay is energized. If the power fails, the relay turns off. The internal battery does not power the relay, so it does not help turn on the relay. Therefore, when planning the system layout, this must be taken into account, for example, power the Umbrella and the boiler from the same UPS;
      • ZONT H-1V - the boiler heats up when the relay is de-energized. Therefore, if the power fails, the relay turns off, but the boiler is turned on by the relay contacts. The umbrella can be hung without a UPS, it will know about the power failure and send an SMS about it;
    • the battery in the H-1V is built-in, and in the H-1 it is not even included in the basic kit. It can be purchased;
    • and most importantly, the firmware of both options are the same. Schemes, almost the same. different cases;

    Connection to the boiler WAMOS QX (EVAN)

    (This scheme is not suitable for other Evan boilers)

    The umbrella, wanting to turn on the boiler, closes 1-3, opens 1-2.

    The boiler has an input IN. Although it is called an air temperature sensor input, we use it as an input for connecting a thermostat. You can use another, alternative input - a floor heating sensor. They are essentially the same.

    Relay ZONT H1 is connected as follows. The central contact of the relay (1) is connected to the IN input. The normally closed relay contact (2) is connected to the "-" input. The normally open relay contact (3) is connected to the "+" input.

    To make it clear, the "+" and "-" contacts of the boiler are connected to a 5V power circuit. As a result, the ZONT H1 relay switches them to the IN input.

    Test of the first switching on of the boiler, using the example of EVAN WARMOS QX

    1. Set the set temperature lower than in the room. Make sure that the boiler inlet is ZERO. The boiler should not heat;
    2. Set the set temperature higher than in the room. Make sure that there is +5V at the boiler inlet. Actually, the boiler must heat the water, and without a multimeter it will be seen that the pipe is heating up hotter and hotter.

    Thermal sensor

    All sensors are connected in parallel. The web interface has a procedure for assigning a "own name" to each sensor.

    Please note that there are many modifications of these sensors on the market and they differ in discreteness. The product comes with a DS18S20 sensor with a resolution of 0.1 degrees. Sometimes users buy sensors on the side. Therefore, we provide additional information on different types of sensors:

    • DS1820 is an old, discontinued model. Differs in the extended case from all new models. It has a bit depth of 9 bits, which leads to a resolution of 0.5 degrees;
    • DS18 S 20 - Has a bit depth of 12 bits, recommended for use. Note that manufacturers label the chip as DS1820, so you can only tell it apart by the case size, it's shorter;
    • DS18 B 20 - Has a different work protocol. The ZONT H1 program supports 12 bits for it, that is, a resolution of 0.1 degrees;

    If there is already a room thermostat and you want to include ZONT - H in the gap between the boiler and the room thermostat?

    Yes, now it is possible. To do this, you need to connect a room thermostat to one of the thermostat inputs.ZONT.

    This connection allows you to control the boiler both remotely (via ZONT ) and manually, by commands from this room thermostat. The choice of control method is carried out through the Internet service or SMS command "Manual mode".

    When operating from a room thermostat, remote temperature monitoring and all notification modes (on an accident, power loss / restoration, alarm events, etc.) are saved.

    Many are interested in how the digital inputs ZONT H are made?

    • Input 2 - may have options:
    • Input 1 - may have options:

    Relay contacts

    Relay diagram:


    It can be seen that when the power is turned off, contacts 1 and 2 are closed. This must be taken into account, bearing in mind the situation with the loss of power. The boiler is usually switched off when the control contacts are opened and switched on when they are closed. But, there are also alternatives! Then an external relay is required, which inverts the operation logic. This relay is activated by contacts ZONT H.

    Often, ZONT H is connected to the boiler through an Uninterruptible Power Supply (UPS).

    First steps to turn on the GSM thermostat ZONT H

    1. Preparation and setup
      1. Buy a SIM card (standard size, no micro- or nano-SIM) and top up your balance. Minimum requirement - 5-10 mb and 10 sms (while you play with the settings, just spend it);
      2. Before using it in the product, it is better if you already have a personal account set up on the website of the telecom operator. It will help you see the dynamics of spending money and traffic and solve emerging problems.
      3. Set up a suitable place where you record and save accounts and passwords. You will need to do this for the SIM card personal account, for the ZONT web interface, for the access password from the phone. It's amazing how often we forget passwords :-)
      4. Before connecting the device to the boiler - set it up "on the table":
        1. Register yourself on the sitehttps://zont-online.ru/
        2. Register the device on the same site - there is a sign "add device".
        3. Install the SIM card (open the receiving clip, fold it up, insert the SIM card into the slots with the cut corner up, soldering the SIM card to the contacts)
        4. Connect the supplied antenna (there is no internal antenna, so this is a must). Please note that if the room is in the basement or in a poor reception area, then the antenna must be moved as high as possible
        5. Connect the temperature sensor and power supply (AC adapter).
        6. < > Dial in the phone text SMS about resetting to factory settings. There are many letters, and the time for sending will be limited, so we advise you to type the text in advance. Do not send SMS yet.
        7. < The item is optional. Needed if there is no web interface> Dial in the phone text SMS about registration of your phone. There are many letters, and the time for sending will be limited, so we advise you to type the text in advance. WITHserial number write small letters and what needs to be done after the serial number space and be sure to write the word " Telephone ", and write the number without any hyphens between the numbers. Do not send SMS yet.
        8. Connect connectors and apply power
        9. Wait for one of two options for a green signal on the device:
          1. so that it burns constantly and sometimes goes out for a fraction of a second several times in a row (indicates that there is a network and the signal level is normal). This is an option when there is both a GSM connection and a connection to the server;
          2. so that it flashes in a series of flashes, at least two flashes, with a pause between flashes.This is an option when the GSM connection is established, but there is no connection to the server. In this case, SMS can be used.
        10. EIf the green indicator flashes only for a short time once, then there is no GSM connection and it is pointless to send SMS.
        11. < The item is optional. Required if the SIM card is NOT a MEGAFON or the device was released before September 2015> Send SMS with APN hotspot setting. How to do this is written in the instructions.
        12. Log in to the web interface and wait for the device to connect. After that, you can add a phone number for voice and SMS notifications in the web interface settings. If this is done, then there is no need to send an SMS with the same number. That is, paragraph 14 is not required.
        13. <The item is optional. Most likely, it will be required in case of repeated passage of the procedure. If the first pass for some reason did not work out>Send SMS for factory reset.After resetting to factory settings, you will need to remove the device from the list and add it again.
        14. <The item is optional. Required if there is no web interface>Submit SMS about registration of your phone. Wait for the response message "phone number set".
    2. Before connecting to the boiler
      1. Try to find out the type of connection (normally closed or normally open), it depends on which contacts on the block to connect the wire from the boiler. To do this, you need to study the documentation for the boiler. You can simulate by connecting a jumper and make sure that the boiler reacts correctly
      2. Install the device and sensors permanently
    3. Connection
      1. Connect the wires from the boiler
      2. Change modes and monitor the reaction of the boiler
      3. As soon as the boiler began to adequately respond to the control action, you can start setting up the modes

    Backup battery and UPS

    The backup battery in the ZONT thermostat is intended only to inform the server and the owner via SMS about the loss of the main 220V power supply. Normally the boiler cannot operate without the main power, so there is no point in controlling the boiler in this situation.

    Sometimes the user installs a UPS - an uninterruptible power supply. It is connected to the boiler and it is logical to feed ZONT from it. But, there is a problem, ZONT does not recognize the loss of the main 220V power supply. In this case, you can take "Boiler alarm" for notification. You can buy any cheap power supply or charger with an output voltage of 5V and connect it to this input. The circuit, unfortunately, requires a couple more parts - a resistor (any) and a diode (any):


    Set Input 2 in the web interface to ground fault mode.

    Some UPSs have a main power failure output. Then you just need to connect it to Input 2 and select one of the "Input Polarity" options - "open" or "short".

    It is important to add that SMS and web notification will be not only when an accident occurs, but also when it disappears.

    The color of the wires of the temperature sensor supplied

    The two strand wire used is misleading to some. It is worth taking a closer look, the one that is "more red" we will call "red". The one that is "blacker" we will call "black". If it's not at all clear, don't be afraid. Turn it on at random and if the sensor works, you will take the readings in the web interface. You can warm one in order to distinguish between several connected in parallel.

    How often is data sent to the server?

    Sensor readings are sent to the server once a minute. Emerging events (out of tolerance, etc.) - immediately upon occurrence.

    Some non-important parameters (information about balance, GSM signal level, etc.) are sent upon request from the server. The server sends requests for this data once every minute or two, but only if the user is online in the web interface or mobile application.

    If the web interface does not feel user activity for 10 minutes, then it goes into "sleep mode". In this mode, the web interface stops updating data from the server as you move the mouse. Temperature and event data continues to be sent to the server in real time.

    Setting Explanations Input 1

    General comment. On the "Status" tab, the "Security" button appears for the options "motion sensor", "delayed motion sensor", "short-to-minus sensor", "minus open sensor". This button can be enabled or disabled, i.e. make the input active or disabled.

    For other options, the "Protection" button is absent, that is, it is considered that the input is constantly active.

    • "not used" - should be selected if it is not connected. Otherwise, you may receive an alarm
    • "delay motion sensor" - triggered when the circuit is opened. At the same time, the delay is 30 seconds. The web interface displays the message "motion detected"
    • "motion sensor without delay" - triggered when the circuit is opened. The web interface displays the message "motion detected"
    • "water leakage sensor" - analog input is used, operation at voltage less than 2.4V. The web interface displays the message "water leak detected"
    • "gas leak sensor" - is triggered when the circuit is interrupted to ground. The web interface displays the message "gas leak".
    • "alarm button
    • "short circuit sensor"- is triggered by a ground fault
    • The ZONT H-1V thermostat model has a 220VAC relay, but also a limited current.