Air conditioning has become a part of everyday life for most people. It is used at home, in offices, shopping centers - almost everywhere. With its help you can easily and quickly both cool and heat a room. But with huge demand, most consumers do not really know about all its capabilities. No fewer people have little understanding of the symbols of the buttons on the air conditioner remote control. This article will help you understand this issue.

Types and features

Air conditioner remote controls are divided into:

  • infrared;
  • wired.

Infrared remote controls are those that transmit a signal through radiation. This system is used in wall-mounted split systems, cassette, ceiling air conditioners, as well as in some models of window air conditioners. Infrared remote controls are convenient to use, but their range is limited to 8 meters, and it must be taken into account that after 5 meters malfunctions may occur due to bright lighting. This type of control is not suitable for systems installed above the recommended values, as well as for those models whose internal units are hidden behind suspended ceilings or plasterboard structures.

Infrared remote controls have a self-diagnosis system, so during a failure, the indicator lights on the internal unit of the split system begin to flash, thanks to which the service department will need less time for diagnostics and repairs.

Wired ones control the air conditioner at any distance. If there is a malfunction, an error code is displayed on the display, which makes diagnostics even easier than with an infrared remote control. The wired type of control allows you to control the operation of 4-8 air conditioners. Some models also include a temperature sensor to help ensure optimal performance.

NEAT

Regardless of the manufacturer of the split system, you can highlight the main symbols on the air conditioner remote control.

NEAT - heating, temperature up to 30 degrees. This mode is used to heat indoor air. It is marked on the air conditioner control panel in the form of a sun. The program automatically adjusts the temperature to the set temperature as soon as it starts to drop. It is important to know that each device has its own limitations when used in cold weather. Operational restrictions can range from -5 to -15 degrees depending on the technical characteristics of the air conditioner. Do not neglect the rules for operating the device to avoid breakdowns. When choosing an air conditioner, it is important to know the conditions under which it can be used. There are models that have no restrictions.

COOL

This mode cools the room in hot weather to 16-18 degrees. This function is considered the main one and is present in any air conditioner. It is marked on the air conditioner remote control in the form of a snowflake. Cooling occurs thanks to the filled refrigerant, which slowly takes heat from the room due to gas formation and releases warm air to the street. The power of the air conditioner should be selected at the rate of one kilowatt per 8-10 square meters, under such conditions the device will work most optimally. When using the cool mode, the most favorable temperature is 16-18 degrees; if this is not enough, you can turn on the fan.

DRI

The dehumidification function is designed to change the set temperature by several degrees for active removal in the room. This mode is identical to COOL, but at very low fan speeds of the indoor unit of the split system. Combining the function with room cooling means providing more comfortable air. The DRI mode helps to quickly dry the space and get rid of high humidity, make it easier to tolerate heat and stop the development of mold. Some air conditioner models have special sensors that automatically turn on this function if there is a deviation from the norm. For example, there is this designation on the Gree air conditioner remote control. In this mode, humidity levels cannot be programmed and maintained.

Air dehumidification occurs in this way:

  • The fan is active for the first 10 minutes.
  • The next 5 minutes are on pause.
  • Then intensive ventilation is carried out for 2 minutes.

This mode should not be used near open sources of moisture, such as a swimming pool. In this case, other drying methods should be used.

FAN

The function is similar to a fan; it is used to change the blowing speed of the air conditioner. In this mode, cooling and heating equipment does not function, but only air is taken from the street. Suitable for homes with central heating. In some models, you can only turn on the ventilation of the room without taking air from the street. Manufacturers most often provide customers with a choice of 3 rotation speeds, and the mode independently selects the most suitable blowing speed.

AUTO

The function maintains a room temperature of 22-24 degrees, as it is considered the most comfortable for humans. The setpoint is adjusted every half hour. In this mode, temperature indicators are not displayed on the control panel display.

TURBO

A mode in which air flows at high speed throughout the room. If it is possible to turn off the air intake from the street, you can quickly mix the layers of air. Thus, the temperature in the room will be the same.

SLEEP

The mode is used during sleep to create favorable conditions. In this mode, the temperature changes over 6-8 hours, gradually increasing or decreasing the air temperature by 1 degree in order not to overcool or overheat a sleeping person. If the air conditioner works for heating, then the temperature increases, if for cooling, it drops.

SWING

Using this mode, you can fix or change the position of the split system blinds. Thanks to this mode, the air is distributed evenly throughout the room. Some consoles display the movement of the blinds.

AUTORESTART

This mode is not indicated on the control panel, but its presence is very important. This program is triggered by an unexpected power outage, independently resuming the operation of the air conditioner in the specified mode, when the electricity appears again.

Standard modes

The main functions of the air conditioner are: dehumidification, cooling and heating the air in the room. The modes and their designation on the air conditioner remote control should be studied in advance in order to know the technical capabilities of the equipment. Cooling occurs due to the transition of the liquid state of the refrigerant into a gaseous state, which is carried out due to the intake of warm air from the room, and when heated, the process occurs vice versa.

Each air conditioner has basic modes and additional ones, which directly depend on the manufacturer and model of the device. Designation of icons on the air conditioner remote control:

  • Cool - cooling, looks like a snowflake.
  • Heat - heating, indicated on the air conditioner remote control by the sun.
  • Dry - dehumidification, image of a drop.
  • Fan - a fan with a corresponding pattern.
  • Sleep - night mode, star image.
  • Lock - child protection.
  • Led - backlight display for working in the dark.

Special abilities

Some manufacturers, in pursuit of consumers, are trying to improve air conditioners with additional options. Some of them become very useful as a result of operation. So, the special features are:

  • Comfort setting - is able to turn on the air conditioner in the mode of calculating the optimal mode. As a rule, in this mode, 20 degrees for heating is considered optimal, 25 degrees for cooling the room.
  • Air purification - occurs thanks to the built-in filters of various degrees of purification. It can be rough - it helps to remove large particles of dirt, and fine - it can even cope with pollen. In addition, the air conditioner can be equipped with filters that absorb odors. Street dust settles on the filters, and the air in the room always remains fresh. This designation can be found on the Samsung air conditioner remote control.
  • 3D flow - directs vertically. The consumer uses this function when he is afraid of catching a cold. It will be marked lfeel on the air conditioner remote control.
  • Ionization - saturates the room with ions with negative charges. The option is intended to improve a person’s immunity and well-being. In the reviews of some consumers it is said that during ionization there is a feeling of a breeze. There is this designation on the LG, Mitsubishi air conditioner remote control in some models
  • Air filtration and purification - this function is not available in all models of the air conditioner, it is carried out due to stepped filters. It helps to clean the air of dust, dirt and various microorganisms, and also helps to get rid of unpleasant odors. This function is indispensable for people prone to allergies and pet owners.
  • Defrosting the heat exchanger - maintains the performance of the air conditioner for a long time. In this mode, during cooling, the load on the refrigerant during the collection of cold is reduced.

The set of additional functions directly depends on the manufacturer and model of the split system. The symbols on the Mitsubishi air conditioner remote control will differ from the same meanings from other manufacturers. Before purchasing a unit, you need to consult with the seller or familiarize yourself with the options using the instructions included in the kit.

So, each air conditioner is equipped with the following functions: dehumidification, heating and cooling of air. In addition, each manufacturer tries to surprise the consumer and diversify the capabilities of the device. Therefore, when choosing an air conditioner, it is important to study the set of functions of the model you like.

1. Saving electricity consumption

Controlling "felt temperature"

I SEE is an infrared sensor that scans the temperature at the floor surface in a 150-degree segment, and the control system can calculate the temperature perceived by a person.

Traditional air conditioners measure the level of air temperature at the entrance to the unit, and it is usually located high, and the temperature below the room may not always be optimal for the user. I SEE remotely measures the temperature in the lower sector of the room, which makes this function indispensable for children's rooms.

Zoned heating and cooling

I SEE - an infrared sensor - scans the temperature near the floor surface in a selected zone and reduces the area where the temperature differs significantly from the target values. This mode zone-conditions rooms, providing comfort and reducing energy consumption.

Econo Cool mode

Increasing the set temperature by 2C during cooling reduces energy consumption by 20%. And in order for the user not to pay attention to the increase in temperature and loss of comfort, the air conditioner provides a special algorithm for the operation of the blinds.

The air is supplied either vertically or horizontally downwards, in turn. The microprocessor calculates and sets the intervals and duration of the cycles, taking into account the temperature of the evaporator and the temperature in the room at the moment.

"I Feel" mode

When not knowing the comfortable temperature level for a person, the user often sets a very low temperature on the remote control - 16C in summer, and 26C and higher in winter. “I Feel”, using a microprocessor, independently determines the optimal temperature for the user, self-learning taking into account the previous parameters.

Performance mode

An external signal can limit system performance and, as a result, power consumption. In this mode, power consumption is reduced to the value set by switches SW7-1, SW7-2 located on the control board of the external unit:

0% (off) – 50%-75%-100% (no restrictions).

2. Appearance

Decorative panels

Elements of decorative panels made of plastic and metal are painted in bright white, appropriate in the color schemes of any interior.

Automatic damper

The damper is horizontal and closes automatically when switched off. Completely closes the hole from which air and parts of the air distribution system come.

3. Air purification

Double plasma cleaning

Dual Plasma - a filtration system - works on the principle of the disintegration of large molecules in an electric field, ionization of molecules, and neutralization of radicals with a catalyst. Due to this, the system captures micro- and nanodust particles and aromatic compounds.

Filtration

The air is cleaned of dust and pollutants, creating a healthy atmosphere in the home.

Antioxidant filter

A filter with a catalytic coating from the group of flavonoids reduces free radicals to chemically inactive molecules. The substance itself is not consumed. Due to this, the filter operates for up to 10 years.

Mitsubishi Electric has introduced an antioxidant into ceramic fibers embedded in a polypropylene mesh, so the filter can be easily washed and wiped, unlike filters in which catalysts are applied to polypropylene in the form of a film that is quickly erased during operation.

Oil filter

Holds oil suspensions and prevents oil from entering the block.

Air flow

Fresh air enters the room, which improves its composition and quality.

Enzyme anti-allergen filter

Eliminates bacteria and dust. Allergens do not accumulate in the filter, being decomposed by catalysts into safe compounds.

Long life filter

Polypropylene filter fibers are specially “activated” for filtration and increase the interval between service treatments.

High efficiency filter

Additionally, it filters the air and retains small particles that have passed through the pre-filter.

Filter check reminder

At selected intervals, a reminder appears to prompt you to clean the filter.

4. Air distribution system

Swing of the horizontal damper

The presence of this mode allows you to evenly distribute air throughout the room.

Swing of vertical guides

This mode supplies air to all areas of the room evenly.

High ceiling rooms

For them, an increase in the flow rate and speed of air flow at the outlet of the indoor unit is provided in order to achieve the required air mobility at the bottom of the room.

Low ceiling rooms

They are designed to reduce the flow rate and air flow rate at the outlet of the indoor unit in order to achieve low air mobility in the working area of ​​the room.

Automatic fan speed

When approaching certain temperature parameters, the fan speed in the indoor unit decreases automatically.

Powerful air flow

To condition a large area or complexly shaped rooms, a wide air flow is required (150 degrees when heating, 100 degrees when cooling. “Wide Swing” button on the remote control with a choice of air supply method from seven proposed options) and a long flow length (“Long Airflow” button , when pressed, the length of the air jet increases to 12 m).

5. Comfort and convenience

24 hour week timer

Organizes the automatic operation of the air conditioner during the week. For each day of the week there are 4 on/off switches and a change in the set temperature.

12 hour timer

The timer is set for the next 12 hours. The discreteness of its installation is 10 minutes.

“I Save” mode

One press of a button puts the system into a low power consumption mode. This is convenient to use when the user goes to bed and uses the “I Save” mode button to change the air conditioner to heat the air to 18C. In the morning, the same button will reset the system to the previous setting of 22C.

This function is also convenient when used in economical standby heating, for example, in a country house. Models MSZ-GE/MUZ-GE are able to maintain a standby temperature of +10C.

Automatic mode change

The system automatically switches cooling or heating modes to maintain the set temperature.

autorun

The air conditioner returns to the previous set mode automatically if, for example, the power was previously turned off.

Cooling at low temperature

The outdoor unit control changes the fan speed to stabilize the refrigerant condensation pressure, allowing the room to be cooled when the outside temperature is low.

"Night" mode (external unit)

The noise level of the external unit is reduced. It is necessary to take into account that productivity in this mode is also reduced.

Limiting electricity consumption

A DIP switch on the control board of the outdoor unit sets the power consumption limit.

Fixing the operating mode

The DIP switch on the control board of the external unit can fix the operating mode. For example, in summer users will not be able to turn on the air conditioner in heating mode, or in winter - in cooling mode.

6. Management and control

Control panel PAR-21MAA or PAR-30MAA

It is possible to connect these remote controls with many functions, a built-in weekly timer and a Russified interface.

Central on-off

Air conditioners are connected to the central controller MAC-821SC-E, which is responsible for switching on/off and indicating the status of groups (no more than 8).

Group management

One remote control can set operating parameters simultaneously for several (up to 16) air conditioning systems.

Connection to MXZ multi-systems

The indoor unit can be used as a component of inverter multisystems based on MXZ external units.

Synchronous multisystem

From two to four (depending on modification) internal units can be connected to one external one. The indoor units in this system will work synchronously. This multi-system is optimal in large mono-volume rooms.

M-NET signal line

The described devices can be connected to the signal line of multi-zone system controllers (M-NET controllers), for example the AG-150A controller.

Rotation, inclusion of an additional system and redundancy

Rotation and redundancy: 1. The main and backup systems alternately operate at a given interval, equalizing the operating time. 2. If the working system fails, the standby system is switched on.

Additional system: 1. When the temperature rises and exceeds the set value by a set value (4, 6, 8C), the backup system is turned on in addition to the operating main one. 2. When the set temperature drops by 4C, the backup temperature is turned off. 3. This function only works when the backup is in cooling mode with the rotation function active.

Automatic connection correction function

Determines the compliance of connections of freon wires and signal lines. In case of discrepancy, correctness is automatically restored - programmatically. It takes 10-30 minutes to check for correctness.

*the function is used only in cooling mode when the outside temperature is above 0C. Sometimes the mode cannot determine the correctness - when the valves are closed, there is a refrigerant leak, expansion valves are faulty, etc.

Built-in drain pump

Organizes the rise of the drainage line and effectively removes condensate.

Collecting refrigerant into the outdoor unit

To condense freon from the line into the external unit (when dismantling or moving the system), a “Refrigerant collection” button is provided.

Flange connections

They simplify installation without requiring soldering of freon wires.

7. Service

Collapsible body

Elements of the air distribution system can be removed for cleaning without using special tools. Cleaning interior parts promotes cleanliness and comfort in the room and increases energy efficiency.

Self-diagnosis

The fault code is displayed on the remote control display, which simplifies diagnostics.

Fault code archive

When the system is operating, fault codes are recorded in non-volatile memory and can be checked during diagnostics.

Anti-mould coating for drainage tray

The drain pan is coated with a compound that prevents the appearance and growth of mold.

Mitsubishi wall-mounted air conditioners are available in two series:

  • Household M-series;
  • Semi-industrial.

Mitsubishi household wall-mounted air conditioners operate on environmentally friendly refrigerant. These are 12 models with an inverter and 2 models without an inverter, characterized by high reliability and build quality.

Advantages of mitsubishi electric air conditioners:

  • Equipped with a daily timer;
  • In automatic mode they work according to the I FEEL system, based on the sensations of people in the room;
  • There is an auto-restart option, the settings are remembered.

Performance range from 1.5 to 7.1 kW.

Inverter air conditioners mitsubishi (Mitsubishi)

Mitsubishi semi-industrial inverter air conditioners are represented by 3 types of outdoor modules. These are the Standard, Zubadan and Power series.

Power range from 3.5 to 25 kW. Each series has models operating on 220 and 380 Volts.

Semi-industrial inverter air conditioners mitsubishi (Mitsubishi) are distinguished by increased routes up to 120 meters, with a height difference of up to 50 meters.

One external module is able to serve 4 internal ones.

  • Models of the ZUBADAN series operate at external temperatures up to -25 for heating and up to -15 for cooling;
  • Advanced self-diagnosis system;
  • When installing mitsubishi Power series inverter air conditioners, you can use tubes of several sections. These models are suitable instead of outdated ones that were charged with R22 refrigerant;
  • The power of Mitsubishi air conditioners of the ZUBADAN series does not change when the outside temperature drops to -15 degrees. Further, the figure gradually decreases, but it is higher than that of conventional other inverters, including the Power series.

Split systems mitsubishi (Mitsubishi)

Mitsubishi split air conditioner is one of the market leaders. The success is explained by the high reliability of models in all price ranges. During the production process, split systems are subjected to serious tests, which significantly exceed the loads possible in real life.

Operating at maximum power in dusty air, in frost or heat is not a problem for Mitsubishi split air conditioners. The advantage over equipment from other manufacturers is the ability to use even at low temperatures. Air conditioners (Mitsubishi Heavy) will not be damaged by temperatures below -20 degrees.

The length of the route during installation can reach 25 meters, and the difference in heights can be up to 12 meters.

Very easy control of air conditioners, innovative solutions for mitsubishi air conditioner remote controls make their use simple and comfortable.

The minimum noise level and quiet modes allow them to be used at night and in children's rooms.

Mitsubishi air conditioners purify indoor air thanks to plasma filtration and an antioxidant purification system.

Most mitsubishi heavy air conditioners operate in hot-cold mode. You can also find economy class models that only cool the air. Without exception, all models of Mitsubishi air conditioners operate on safe R410a freon.

Multi-split systems are the ability to connect several indoor modules to one outdoor module and simultaneously serve the entire apartment or multi-room office. This is not a cheap technique, but you have to pay for quality.

Mitsubishi cassette air conditioners

The corporation produces single-flow and four-flow Mitsubishi cassette air conditioners, all models operate on inverter control.

Single-flow cassette air conditioners Mitsubishi MLZ-KA-VA series are convenient for installation in rooms equipped with a suspended ceiling. The indoor unit fits in the opening between the main and false ceiling, which is at least 17.5 centimeters.

Technical features:

  • Control is carried out using a wireless remote control for the Mitsubishi air conditioner;
  • The direction of the air stream can be changed;
  • The module is equipped with a drainage pump and a flexible tube for draining water;
  • The air conditioner comes with brackets for attaching to the ceiling;
  • There is no need to equip a special hatch for repair and cleaning.

The power of mitsubishi electric air conditioners is 2.5 – 3.5 – 5 kW.

Four-flow cassette split systems SLZ-KA are designed for installation in suspended ceilings. Case dimensions 600 x 600 mm, depth 235 mm. The air dampers have separate drives, the direction of each air flow can be adjusted separately.

Technical features:

  • Works for cooling at -15 outside;
  • Equipped with a drainage pump;
  • Equipped with two control panels: wireless and wired with a color luminous screen, menu and instructions for the mitsubishi air conditioner in Russian.

Duct air conditioners Mitsubishi

Mitsubishi duct air conditioners are designed for halls of complex shape, multi-room offices or apartments. Cooled air enters rooms through ducts or ducts. The air conditioner module is mounted in a utility room or under a suspended ceiling, and the air ducts are also located here. For proper installation, it is advisable to plan this type of climate system at the stage of building construction. During installation, the data from the Mitsubishi air conditioner instructions is used.

Mitsubishi duct air conditioners are able to renew indoor air by sucking in fresh air from the street. To use this function, you need to install a separate channel with access to the street.

Remote control for mitsubishi air conditioner

The control panel looks very ordinary. The location of the buttons is quite convenient, and even a child can understand the functions. To the extreme, all functions are always described in the operating instructions for the remote control.

Mitsubishi Electric Corporation is a Japanese brand. A world-famous brand of manufacturer of a wide range of various electrical equipment and technical systems. There are a number of companies that have the word “Mitsubishi” in their name. And although formally there is no scheme that includes all these companies in a common holding, nevertheless, they are conditionally interconnected.

Main production of Mitsubishi:

  • air conditioning equipment (domestic, semi-industrial, industrial air conditioners);
  • heating equipment (heat pumps, heaters, boilers, etc.);
  • industrial automation;
  • information and communication equipment;
  • power equipment;
  • equipment for apartments, kitchen, home;
  • automobile spare parts;
  • and other electronic equipment.

Currently, the company develops and produces both narrow, specialized devices and consumer goods. The range of manufactured products covers almost all manufactured electrical equipment - from batteries to space technology. The company's products meet the highest standards.

The company is the undisputed world leader. Therefore, you can often find fakes using the logo.

Numerous offices, production sites, and service centers are scattered almost all over the world. With the exception of Japan itself, there are more than 100 different structures around the world. The main research centers are located in Japan.

Air conditioning systems Mitsubishi Electric

The company produces a full range of climate control equipment. In many respects, air conditioning systems are conventionally divided according to their purpose into industrial, semi-industrial and household. The border between them is blurry. This means that the equipment is applicable in different places and rather the determining factor of feasibility will be the price - acquisition, operation, rotation, subsequent disassembly and disposal.

Industrial air conditioners

We will not consider it in detail. The choice of equipment largely depends on the purpose of the application. Such equipment is subject to increased requirements, both in terms of microclimate support and operational reliability. Such equipment is installed in server rooms, medical, scientific laboratories, etc. Very precise (up to one degree) temperature support is often required, which is provided by precision systems. Usually they combine a whole cascade, which is synchronized through a special matcher. The composition includes spare, backup equipment.

Such complexes are planned individually to order and talking about some series of industrial equipment can be quite conditional. In fact, in many cases the same standard semi-industrial equipment is used: multi-split systems, duct, cassette, etc. Most often, floor blocks are used as the final device. This is due to the need for high cooling capacity, high power of the equipment, and accordingly the dimensions and weight of the equipment can be impressive. A water cooling pipe system is supplied to it.

Semi-industrial models

They are divided into monoblock and multiblock. Monoblock systems are single-flow systems in which cooling and removal of excess heat are implemented in one unit. To remove excess heat, it is necessary to either place the equipment directly on an external wall or install an air hose. Such systems are mostly classified as industrial (it is easier to increase accuracy in one device).

Two or more block systems have become more widespread. The usual implementation scheme is one external vrv unit and one or more internal ones (vrf - multi-zone system). Sometimes the system is closed through several external units in anticipation of duplication in the event of failure of one of the units.

The following system markings are accepted:

  • PLA – cassette;
  • PKA – wall mounted;
  • PCA – ceiling;
  • PEAD – channel;
  • PEA – high-pressure;
  • PSA - columnar.

The manufacturer even has specific models positioned exclusively for wine cellars.

Household wall appliances

Mobile air conditioners have also been added to household air conditioners. But this is rather an exception; the company practically does not produce such systems and it is difficult to find them on sale.

The company has adopted the following markings for household systems. First, information about the indoor unit is indicated, followed by a fraction about the outdoor unit:

  • The first letter is series (M or S);
  • Second letter. U – outdoor unit, S – wall-mounted, F – floor-mounted, E – duct, L – cassette;
  • Third letter. Z – inverter air conditioners, H – without inverter. The absence of a letter means that the system is non-inverter and works only for cooling.

The remaining icons indicate different types of models. For example, the letter H means that a heating element is built into the pan, which heats the outdoor unit in winter.

Comparative characteristics of several models

For comparison, we present the characteristics of several models.

Model MSZ-HJ25/MUZ-HJ25VA MSZ-FH50VE/MUZ-FH50VE MSZ-SF35VE/MUZ-SF35VE
Type wall split system wall split system wall split system
Power (cooling/heating), W 2500/3150 5000/6000 3500/4000
Power consumption (cold/heat), W 730/870 1380/1550 1080/1030
Noise level of the indoor unit (max), dBA 43 46 46
Maintenance of rooms up to sq.m. 20 50 35
Range of external air temperatures (heating), ºС -10 – +24 -15 – +24 -15 – +24
Range of external air temperatures (cools), ºС +15 – +46 -10 – +46 -10 – +46
Refrigerant refill R410A R410A R410A
Estimated cost, rub. 30 000 – 50 000 100 000 – 150 000 60 000 – 80 000

Instructions for the control panel and air conditioners Mitsubishi Electric

The instructions for Mitsubishi Electric air conditioners contain a description of the main operating modes of the equipment, recommendations for installation, configuration, dismantling, service, as well as explanation of errors.

Installation of the Mitsubishi Electric air conditioner must be carried out by specialists who have the appropriate certificates. Otherwise, various negative consequences may occur. Incorrect independent connection by the user and subsequent operation may lead to equipment failure.


The Mitsubishi Electric split system, as well as multi split systems, consist of an external unit, which is usually mounted on a bracket to the wall of the house. Work can only be carried out by installers with the appropriate equipment and skills; in case of modifications, for example, installation of a winter kit, it is also necessary to contact specialists.

The remote control for the Mitsubishi Electric air conditioner can be of various modifications. The overview of functions on the remote control varies depending on the specific equipment. All remote controls provide control of the main operating modes: cooling, heating, dehumidification, ventilation. There is a timer mode. Other extensions are usually built into remote controls that come with devices that enable the corresponding modes: cleaning, ionization, fresh ventilation.

Error codes for Mitsubishi Electric air conditioners

Mitsubishi Electric air conditioner error codes are standardized and universal. This means that the fault tables are largely similar in the data sheets of different models. And although there are no fundamental differences, it is recommended to use only the native manual.

The multi-diagnostic system has been developed. The program queries the status of sensors located in all main components of the equipment (compressor, inverter board, fan motor, evaporator, etc.) and based on the test results, possible faults are indicated. The reaction depends on the severity of the malfunction and on the specific model: stopping the equipment, partially blocking functions, turning on the purifier mode, etc. In any case, a notification will be generated for the user about how the system works.

The model range is very diverse and each model may have its own characteristics. In most cases, operating parameters are displayed on the remote control. In developed systems, not only critical failures can be displayed, but also various regulatory and informational messages can be displayed: the need to replace the filter, pressure in the tubes, condition of the motor, pump, adapters, etc.



In addition to being reflected on the remote control, messages can be duplicated on the indicator, which is located on the body of the indoor unit, or under the cover. In models that do not have an indicator and a remote control, only a number of LEDs blink. A malfunction is indicated by selecting combinations of duration, frequency and order of LED flashing.

If a malfunction is indicated (without obvious signs of failure), it is recommended to restart the system. To do this, turn off the automatic fuse (a specialist must install a separate circuit breaker in the electrical panel), wait a few minutes and turn it on again. If performance is not restored, contact service. Repair of the Mitsubishi Electric air conditioner should only be carried out by a specialized service center. You can only change or clean the filter yourself, external cleaning, and in some cases flushing the drainage channels. If the equipment is disassembled before the warranty period expires, it may be voided from warranty.

Precautions 1
Recycling 7
Title of each part 8
Preparations before starting work 10
Select operating modes 12
Adjusting the air flow direction and fan speed 15
Economy cooling mode 16
Using Timer 16
Cleaning your air conditioner 17
If you think there is a problem 18
When the air conditioner will not be used for a long time 21
Installation location and electrical work 21
Characteristics 23

Precautionary measures
Since this device contains rotating elements and conductors,
touching which may result in electric shock, be sure to
Read these "Precautions" before use.
. The information contained in this section is important for your safety before
be sure to study it using it!
. After reading this manual, keep it along with the installation manual in
accessible place.

Signs and their meanings
WARNING!: Improper implementation of these recommendations with high
is likely to lead to dangerous consequences such as death, serious
injuries, etc.
ATTENTION!: Failure to follow these recommendations correctly may result in
occurrence of a dangerous situation during operation.

Meanings of symbols used in this manual

Make sure you don't do this

Be sure to follow the instructions.

Never insert your finger or stick or similar
items.

Never stand on the indoor/outdoor unit or place
objects on them.

Electric shock hazard. Be careful.

Be sure to unplug the power cord from the outlet.

Be sure to turn off the power

WARNING!
Do not connect the power cord of the air conditioner to an extension cord.
or connect multiple devices to one outlet.
. This may result in overheating, fire or injury.
electric shock.
Make sure the power cord plug is clean and securely inserted into the
socket.
.dirty plug may cause fire or damage.
electric shock.
Do not tie, pull, damage or modify the cable
nutrition. Do not heat it or place heavy objects on it.
items.
. This may result in fire or electrical shock.
electric shock
Do not turn OFF/ON switch or try to disconnect/
connect the plug during operation.
. This may create sparks, which may cause a fire.
. Only after turning off the indoor unit using the remote control
remote control is allowed to switch the switch in

OFF position or disconnect the plug.
Do not expose yourself to cold air during
for a long time.
. It may be harmful to your health.
It is prohibited to install, move, disassemble,
change or repair the air conditioner.
.Improper handling of the air conditioner may result in
fire, electrical injury or water leakage

WARNING!
Do not insert fingers, sticks, or other objects into entry points or
air outlet.

speed during operation

WARNING!
If any strange behavior occurs (for example, a burning smell),
stop the air conditioner and unplug it or switch it
switch to OFF position.
. Continuing to operate in this case may result in malfunction,
fire or electric shock. In this case
contact your supplier.

WARNING!
If your air conditioner is not cooling or heating, there is a possibility that
a refrigerant leak has occurred. In this case, contact your
to the dealer. If refrigerant needs to be charged for repairs, call
specialist to clarify all the details.
. The refrigerant used in the air conditioner is safe. Usually
no leakage occurs. However, if a refrigerant leak occurs and
it may come into contact with hot objects, for example
fan heater, kerosene heater or stove,
Possible occurrence of harmful gases.

ATTENTION!
Avoid touching the air intake and aluminum fins
internal and external blocks.
. This may cause injury.
Do not spray insecticides or flammable aerosols onto
device.
. This may result in fire or deformation of the device.
Do not expose pets or houseplants
direct action of air flow.
. This may result in injury to animals or plants.
Do not place other electrical appliances or furniture under
indoor or outdoor unit.
. Water may drip from the device, which may cause damage.
or malfunction of an electrical appliance.
Do not use faulty mounting hardware to install the air conditioner.
elements.
. The device may fall and injure people.

ATTENTION!
Do not use an unstable bench for working or cleaning
air conditioner
. This could cause injury if you fall.
Do not pull on the power cord.
. This can damage individual strands of the current-carrying wire and lead to
to overheating or fire.
Do not charge, disassemble or throw batteries into fire.
. This may cause electrolyte leakage, causing a fire or explosion.
Do not use the device for a long time when
high humidity (80% or more), for example, with doors open
or windows.
. Excess condensation can wet or damage furniture.
Do not use the device for special purposes, such as
storing food, raising animals or
plants, for storing precision instruments or art objects.
. This may degrade the quality of the items and cause damage
animals and plants.

Do not direct the air flow from the air conditioner towards appliances with
open flame.
. This may lead to the appearance of incomplete products in the air.
combustion.

ATTENTION!
Before cleaning the appliance, turn it off and unplug it from the socket.
or set the switch to OFF.
. This may cause injury as the fan rotates at high speed.
speed during operation.
If the device will not be used for a long period of time
time, remove the plug from the socket or set the switch to
OFF position.
. Dirt may accumulate inside the device, which may cause
overheating or fire.
Replace all batteries in the remote control
new, of the same type.
. Using an old battery with a new one may cause
heating, electrolyte leakage or explosion.
If electrolyte gets on your skin or clothing, you should carefully
rinse with clean water.
. If electrolyte gets into your eyes, rinse them with clean water and
Seek medical attention immediately.
Make sure the area is well ventilated when
use of heating devices indoors,
using a combustion reaction.
. Insufficient ventilation can lead to oxygen starvation.
Turn off the switch during a thunderstorm whenever possible
lightning strike.
. The device may be damaged if struck by lightning.
After using the conditioner for several seasons,
additional inspection and maintenance is required
addition to regular cleaning.
. Dirt or dust in the unit can cause an unpleasant odor and contribute to
fungal growth or may clog the water drainage channel, causing leakage
water from the indoor unit. Air conditioner inspection and maintenance
require special knowledge and skills - contact your

supplier regarding this matter.
Do not touch switches with wet hands.
. This may result in electric shock.
Do not wash the air conditioner with water or place objects containing water
such as vases, on it.
. This may result in fire or electric shock.
Do not stand or place any objects on the outdoor unit.
. Injury may occur if you or this object falls.
Air conditioner installation

WARNING!
Contact your dealer to install the air conditioner.
. It does not need to be installed by the user; it is required
availability of special knowledge and skills. Incorrectly installed
air conditioner may cause water leakage, fire or injury
electric shock.
Providing specialized power supply for the air conditioner.
. Failure to provide separate power may result in overheating or
fire.
Do not install the device where there is a risk of leakage
flammable gas.
. If gas leaks and accumulates around the outdoor unit, it may cause
to an explosion.

WARNING!
Ground the device properly.
. Do not connect the ground wire to gas and water pipes,
lightning rod or telephone wire. Improper grounding may
cause electric shock

ATTENTION!
Use a ground leakage breaker depending on the
region in which the air conditioner is used (for example, in regions with
high humidity).
. If a ground leakage breaker is not installed, this may
cause electric shock.
Make sure the condensation has dried.
. If the drainage channel is clogged, water may drip from
indoor/outdoor units, wetting and damaging furniture.
If abnormal operation of the air conditioner occurs
Turn off the air conditioner immediately and contact your dealer.

DISPOSAL
To dispose of this product, contact your dealer.
Note:
This symbol is only valid for EU countries.
This symbol is applied in accordance with Directive 2002/96/EC Article 10 Information
for users and Annex IV, and/or Article 20, Directive 2006/66/EC Information
for end users and Appendix II.

Your MITSUBISHI ELECTRIC product is designed and manufactured using
high quality materials and components that can be recycled and/or
reused. This symbol means that electrical and electronic
equipment, batteries and accumulators at the end of their service life should be disposed of
separately from household waste. If a chemical symbol is printed below this symbol (Fig.
1), This chemical symbol means the battery or accumulator contains heavy metals
in a certain concentration. It will be displayed as follows: Hg: mercury
(0.0005%), CD: cadmium (0.002%), Pb: lead (0.004%). In the European Union there are
separate collection systems for used electrical and electronic products, batteries and
batteries. Please donate this equipment, batteries and accumulators to your
local recycling community. Please help us save
environment we live in!

Title of each part


Preparation before starting work
Before you begin: Plug the power cord into an electrical outlet and/or switch into
ON position
How to set the remote control operating mode.
Depending on the type of air conditioner, it is necessary to set the switch correctly in
Heat-Cold mode or cooling only.


Switch position value.


If selected
Using the wrong mode may damage the device.

Installing batteries in the remote control


Make sure the polarity of the batteries is correct.
. Do not use manganese batteries. This may damage the remote control.
. Do not use rechargeable batteries.
. Replace all batteries with new ones of the same type.
. The batteries can be used for approximately 1 year.
. Gently press the RESET button using a thin tool.
If the reset button is not pressed, the remote control may not operate correctly.

Setting the current time


1 Gently press the Clock button using a thin object.
2 Then, by pressing the time setting buttons, set the hours and minutes

Selecting operating modes


1 Turn on the air conditioner by pressing the button
2 Select the operating mode by pressing the operating mode button
Each repeated press will cycle through all modes.

3 Select the desired room temperature by pressing the buttons
Pressing the power button again will turn it off.

The blinking or glowing values ​​of the lamps in the indicator area on the indoor unit.
Both are on - The air conditioner is working to cool/heat the air to
set temperature.
One is on, the other is off - the temperature has reached the specified temperature.
One is on, the other is blinking - Standby mode (ONLY in a multi-split system).

Multi split.
Two or more indoor units can be served by one outdoor unit.
When several indoor units operate simultaneously, they should be used for
the same task (heating or cooling). If heating is selected on one and
then the second one turns on in cooling mode, then the first one goes into standby mode (standby).

OPERATING MODES
I FEEL mode
In this mode, the air conditioner itself selects the type of operation, depending on the temperature in
indoors. If the temperature is higher than the set one (for example 25° C, but 24 is set), then it
switches to COLD mode. When it reaches 24 ° C, it automatically switches to
DRY . If the temperature is below 23° C, the air conditioner will switch to HEATING mode.
Note:
When operating in COLD mode, it is impossible to change the set room temperature if
its value is higher by more than 2° C. It is necessary to wait until the air cools and only
then change this value.
COOL mode
Cooling the air in the room to a given temperature and maintaining it at a given temperature
level.
DRY mode
Dehumidifying your premises. The air may cool down a little. Desired temperature
cannot be set at all in dry mode.
FAN ONLY mode
Air circulation in your room.
Heating mode
Heating and maintaining warm air at the desired level.

Emergency mode
If you can't use the remote control...
You can control the air conditioner by pressing the emergency button
switch mode. Each press of it will cyclically turn on
the following operating modes.
In the COLD ONLY operating mode, these will be the following modes:

. the second press turns it off.
In COLD AND HEAT mode, these will be the following modes:
. the first press activates emergency cooling;
. the second press turns on emergency heating;
. the third press turns it off.
In this case, the temperature is set to 24° C, the ventilation mode is medium, the mode
horizontal damper operation - AUTO.
Note: for the first 30 minutes the work is carried out in test mode, there is no temperature control,
ventilation mode is switched to maximum.

Automatic resume.
During a power outage, if this function was
turned on on the remote control, after the power appears on the air conditioner
will automatically work in the latter mode. If you want her
disconnect, contact your service representative.

Adjusting the direction of air flow and speed
fan

Click on the button
and select the work intensity from four options: Auto, weak,
medium and strong.
Click on the button
and select the position of the air guide. Modes available
Auto (double beep), five incline levels and swing mode.
In AUTO mode, the most efficient option is selected.
When one of the five manual modes is specified, the air will be directed
at one of five tilt angles.
When you select Swing, the damper constantly oscillates.
You can also manually set the air outlet direction. For what
you need to manually adjust the position of the vertical damper.

Economy cooling mode (“ECONO COOL”).
During COOL mode, press the button to start the operation
ECONO COOL.
The device performs actions aimed at maintaining the specified
temperature. The temperature you set is set 2°C higher automatically.

Using the Timer
Click the buttons


The first will indicate the time the air conditioner is turned on, the second the time to turn off.
To set the time in hours and minutes, use the buttons
Each press increases the value by one unit.
Press again cancels the timer.
Both timers can be used together, in which case one sets the time
on, the second off.

Cleaning the air conditioner
Instructions:
Turn off the power or turn off the circuit breaker before cleaning.
. Be careful not to touch metal parts with your hands.
. Do not use benzine, thinners, abrasives or insecticides.
. Use only detergents pre-diluted in water.
. Do not expose to direct sunlight, heat or fire to dry.
. Do not use water with a temperature above 50°C.


1. Air purification filter (optional)
. If the air purification filter is clogged, this may reduce the power of the device
or cause condensation to form at the air outlet.
. The air purification filter is disposable.
. If the color of the filter turns dark brown, the filter should be replaced immediately.
. It is recommended to change every 4 months for best performance.
. Serial number MAC-1300FT
2. Air filter (catechin air filter)
. Needs to be cleaned every 2 weeks
. Remove dirt with a vacuum cleaner or rinse with water.
. dry in the shade before putting it back.

What is a "Catechin air filter"?
Catechins are bioflavonoids found in green tea, which is known for its
antiviral and antioxidant properties. In addition, catechin has
excellent deodorizing characteristics. Catechin air filter is not only
improves air quality, but also prevents the spread of bacteria and viruses in
indoors.
Note:
. Clean the filter regularly for better performance and reduced
energy consumption.
. Leaving water in the air conditioner for a long time promotes the growth of fungi, such as mold.
To prevent fungal growth, set the temperature to the highest setting.
manual mode and leave the air conditioner to warm up for 3-4 hours. Usually for this
time, the water inside the device dries out.

If you think there is a problem
Even when these points are checked, if the device does not start working normally,
Stop using the air conditioner and contact your dealer.

Symptoms

Possible cause and solutions

Device is not working.

Perhaps the circuit breaker is turned off?
Perhaps the power plug is not plugged into the outlet?
Is the timer not set?

The device does not turn on for 3 days
minutes after switching off.

The microprocessor is programmed this way
necessary to protect the air conditioner. Wait
Please.

In Drying mode it turns off
fan.

To prevent excess water from forming on
elements of the external unit the compressor periodically
turns off, which does not affect the thermal regime
in room. The temperature will be maintained at
according to the value you specify.

Mist is emitted from the air outlet of the indoor unit.

Indoor air contains a lot of moisture and
a stream of cold air that comes out of
air conditioner, causes a similar phenomenon in the area
contact.

Vertical oscillations of the vertical damper in the “Swing” mode periodically stop.

This is normal in this operating mode.

Airflow direction in
horizontal plane fails
adjust using the remote control,
observed periodically
its independent changes

If the Cool or Dry mode is selected and it works
from 30 minutes to 1 hour, then to prevent dripping
condensation from the indoor unit of the air conditioner
automatically selects horizontal
direction for the exhaust air.

During HEATING mode
work stops for 10
minutes.

This is necessary to defrost the external
block. At low outside temperatures
significant freezing by condensate is possible, with
who need to fight.

After the advent of electricity in
network air conditioner yourself
starts working, although no one is there for them
this time was not managed with help
remote control.

If the mains voltage disappears while
the air conditioner worked according to the command received from
remote control, then after the power supply appears in the network, it
will automatically continue to work in the same mode
which one I was working in before the shutdown. Read more in
See "Automatic Resume Feature"
work", see page 14.

Multi split system

The indoor unit, which is not currently
works, heats up and makes sounds
flowing water.

Even if this inner element is not used,
it continues to receive a certain amount
refrigerant, which is normal.

The “HEATING” operating mode is selected, but the device starts to work
only in 10 minutes.

This is normal as it may be necessary to warm up the outdoor unit and remove ice from it.

External unit

Water is leaking from the external unit

When using the HEAT and COLD modes, the tubes and their connections may
cool, which leads to the appearance of condensation on them.
. When operating in the “Heating” mode, condensation may appear on the external unit.
. When operating in the “Heating” mode, ice may appear on the external unit, which will
melt and drip during surgery
defrosting the external unit.

White smoke comes out of the outdoor unit

When operating in the Heat mode, steam is generated that looks like smoke.

Remote control

The image on the remote control display is not
appears or has become dim

Are the batteries drained?
. Is their polarity set correctly?
. Is any button pressed on the remote control?

Heat or cool a room
not satisfactorily
succeeds.

Is the temperature selected correctly?
. Is the operating mode selected correctly?
fan? Increase its power.
. Are the filters dirty?
. Is there any dirt on the fan and
heat exchanger of the indoor unit?
. Are there any contaminations?
ventilation openings for external and
indoor unit?
. Are the windows and doors in the room closed?
. Doesn't it work indoors at the same time?
gas burner or exhaust fan?
In this case, the effect of the work
air conditioner will be lower.
. If the temperature outside is very high, then
the air conditioner will not work properly
effective.
. When the temperature outside is low, heating
will not happen as efficiently.

When heating mode is turned on
Air does not immediately blow out of the device.

Please wait while the device
prepare for the supply of warm air.

Air flow

There was a strange smell
air flow from internal
block.

Are the air filters clean?
. Are the fan and heat exchanger of the indoor unit clean?
. The device may suck in foreign
odors already present in the room (from
carpets, walls) and blow them out.

Sounds

Crackling noise is heard

Sound may occur due to expansion/contraction
plastic when the air temperature changes.

I can hear gurgling

This sound may occur when the outside air
is sucked out of the drain hose when turned on
indoor exhaust device or fan,
which causes water movement in the drain hose.
This sound is also heard when there is strong wind
swings the drain hose.

A mechanical sound is heard from
indoor unit.

The sound may be caused by the compressor or
fan

You can hear the water flowing.

The sound may be caused by the movement of condensation or
refrigerant.

In the following cases, you need to stop the air conditioner and contact your dealer.
. If water flows or drips from the indoor unit.
. When the left operation lamp flashes.
. If the current breaker trips frequently.
. The remote control signal does not reach the room where electronic
fluorescent lamps.
. Operating the air conditioner causes interference to radio or television signals. IN
In this case, a radio signal amplifier may be needed.
. When abnormal sounds occur.

When the air conditioner will not be used for a long time
1. Manually turn on the heating mode and set the maximum temperature
keep the air conditioner in this mode for 3-4 hours. (This is necessary to dry
internal elements and prevent fungal growth).
2. Press the “Power Off” button on the remote control.
3. Remove the plug from the outlet.
4. Remove the batteries from the remote control.
To restart after a long period of inactivity.
1. Air filters need to be cleaned.
2. Make sure that the openings on the outdoor and indoor units are not blocked
air outlet and inlet.
3. Make sure the ground connection is correct.

Installation location and electrical work
Installation location
Not Install the air conditioner in the following places.
. Where there is a lot of machine oil.
. Salty places such as the coast.
. In places where hydrogen sulfide gas forms, for example in hot springs.
. In places where oil products are released or when the area is filled with oil smoke.
. Where there is high frequency or wireless equipment.
. Where the air outlet from the outdoor unit will be blocked.
. Where the noise of the external unit will disturb other people.

Electric installation work
. Provide a separate circuit for powering the air conditioner.
. Be sure to observe the permissible power of the current breaker.
If you have any questions, please contact your dealer.

The installation location of the outdoor unit must be at least 3 m from the TV antenna,
radio, etc. In areas where the signal is weak, greater distance between
the outdoor unit and the antenna of the device if the operation of the air conditioner interferes with radio reception
or television signals.

CHARACTERISTICS

New on site

>

Most popular